 R2023K/T
2-wire Serial Interface Real Time Clock IC
NO.EA-124-070221
OUTLINE
The R2023K/T is a CMOS real-time clock IC connected to the CPU by two signal lines, SCL, SDA, and configured to perform serial transmission of time and calendar data to the CPU. The periodic interrupt circuit is configured to generate interrupt signals with six selectable interrupts ranging from 0.5 seconds to 1 month. The 2 alarm interrupt circuits generate interrupt signals at preset times. As the oscillation circuit is driven under constant voltage, fluctuation of the oscillator frequency due to supply voltage is small, and the time keeping current is small (TYP. 0.45A at 3V). The oscillation halt sensing circuit can be used to judge the validity of internal data in such events as power-on; The supply voltage monitoring circuit is configured to record a drop in supply voltage below two selectable supply voltage monitoring threshold settings. The 32.768kHz clock output function (CMOS output with control pin) is intended to output sub-clock pulses for the external microcomputer. The oscillation adjustment circuit is intended to adjust time counts with high precision by correcting deviations in the oscillation frequency of the crystal oscillator. Since the package for these ICs are TSSOP10G (4.0x2.9x1.0: R2023T) or FFP12 (2.0x2.0x1.0: R2023K), high density mounting of ICs on boards is possible.
FEATURES
* * * * * * * * * * * * * * * Minimum Timekeeping supply voltage TYP:0.66 to 5.5v (Worst: 1.00V to 5.5v); VDD pin Low power consumption 0.45A TYP at VDD=3V (1.00A MAX.) Two signal lines (SCL, SDA) required for connection to the CPU. Time counters (counting hours, minutes, and seconds) and calendar counters (counting years, months, days, and weeks) (in BCD format) Interrupt circuit configured to generate interrupt signals (with interrupts ranging from 0.5 seconds to 1 month) to the CPU and provided with an interrupt flag and an interrupt halt 2 alarm interrupt circuits (Alarm_W for week, hour, and minute alarm settings and Alarm_D for hour and minute alarm settings) With Power-on flag to prove that the power supply starts from 0V 32-kHz clock output pin (CMOS push-pull output with control pin) Supply voltage monitoring circuit with two supply voltage monitoring threshold settings Automatic identification of leap years up to the year 2099 Selectable 12-hour and 24-hour mode settings High precision oscillation adjustment circuit Built-in oscillation stabilization capacitors (CG and CD) Package TSSOP10G (4.0mm x 2.9mm x 1.0mm: R2023T) FFP12 (2.0mm x 2.0mm x 1.0mm: R2023K) CMOS process
1
R2023K/T
PIN CONFIGURATION
R2023T(TSSOP10G)
R2023K(FFP12)
OSCOUT OSCIN CLKC
32KOUT SCL SDA INTRB VSS
1 2 3 4 5
10 9 8 7 6
VDD OSCIN OSCOUT CLKC INTRA
INTRA VSS INTRB
8 2
10 11 12 1 3
SDA
SCL
TOP VIEW
TOP VIEW
BLOCK DIAGRAM
32KOUT CLKC ALARM_W REGISTER (MIN,HOUR, WEEK) ALARM_D REGISTER (MIN,HOUR) VOLTAGE DETECT POWER_ON RESET VSS VDD
32kHz OUTPUT CONTROL
COMPARATOR_W
COMPARATOR_D OSCIN OSC OSCOUT
DIVIDER CORREC -TION
DIV
TIME COUNTER (SEC,MIN,HOUR,WEEK,DAY,MONTH,YEAR)
32KOUT
OSC DETECT INTRA
ADDRESS DECODER
ADDRESS REGISTER
9
7 6 5 4
VDD (VSS) (VSS)
SCL I/O CONTROL SDA
INTRB
INTERRUPT CONTROL
SHIFT REGISTER
SELECTION GUIDE
Part Number is designated as follows: R2023K-E2 Part Number R2023a-bb Code a bb Description Designation of the package. K: FFP12 T: TSSOP10G (Preliminary) Designation of the taping type. Only E2 is available.
2
R2023K/T
PIN DESCRIPTION
Symbol SCL Item Serial Clock Line Serial Data Line Description The SCL pin is used to input clock pulses synchronizing the input and output of data to and from the SDA pin. Allows a maximum input voltage of 5.5v regardless of supply voltage. The SDA pin is used to input and output data intended for writing and reading in synchronization with the SCL pin. Allows a maximum input voltage of 5.5v regardless of supply voltage. Nch. open drain output. The INTRA pin is used to output alarm interrupt (Alarm_D) and periodic interrupt signals to the CPU. Disabled at power-on from 0V. N-channel open drain output. Allows a maximum pull-up voltage of 5.5v regardless of supply voltage. The INTRB pin is used to output alarm interrupt (Alarm_W) to the CPU. Disabled at power-on from 0V. N-channel open drain output. Allows a maximum pull-up voltage of 5.5v regardless of supply voltage. The 32KOUT pin is used to output 32.768-kHz clock pulses. The pin is CMOS push-pull output. The output is disabled and held "L" when CLKC pin is set to "L" or open, or certain register setting. This pin is enabled at power-on from 0v. The CLKC pin is used to control output of the 32KOUT pin. The clock output is disabled and held "L" when this pin is set to "L" or open. Incorporated pull down register. The OSCIN and OSCOUT pins are used to connect the 32.768-kHz crystal oscillator (with all other oscillation circuit components built into the R2023K/T). The VDD pin is connected to the power supply. The VSS pin is grounded.
SDA
INTRA
Interrupt Output A
INTRB
Interrupt Output B 32kHz Clock Output
32KOUT
CLKC
Clock Control
OSCIN OSCOUT VDD VSS (VSS)
Oscillation Circuit Input / Output Positive/Negative Power Supply Input
Please connect to ground line, or do not connect any lines.
3
R2023K/T
ABSOLUTE MAXIMUM RATINGS
(VSS=0V) Symbol VDD VI VO PD Topt Tstg Item Supply Voltage Input Voltage 1 Output Voltage 1 Output Voltage 2 Power Dissipation Operating Temperature Storage Temperature Pin Name VDD SCL, SDA, CLKC SDA, INTRA , INTRB 32KOUT Topt = 25C Description -0.3 to +6.5 -0.3 to +6.5 -0.3 to +6.5 -0.3 to VDD + 0.3 300 -40 to +85 -55 to +125 Unit V V V mW C C
RECOMMENDED OPERATING CONDITIONS
Symbol Vaccess Item Supply Voltage Pin Name Power supply voltage for interfacing with CPU CGout,CDout=0pF *1), *2) CGout,CDout=0pF *1), *2) (VSS=0V, Topt=-40 to +85C) Min, Typ. Max. Unit 1.7 5.5 V *1) 1.00 0.66 5.50 1.00 V
VCLK VCLKL fXT VPUP
Time keeping Voltage Minimum Time keeping Voltage Oscillation Frequency Pull-up Voltage
32.768 kHz 5.5 V INTRA , INTRB , SCL, SDA *1) CGout is connected between OSCIN and VSS, CDout is connected between OSCOUT and VSS. R2023K/T incorporates the capacitors between OSCIN and VSS, between OSCOUT and VSS. Then normally, CGout and CDout are not necessary. For more detail, see "P.30 *Adjustment of oscillation frequency" *2) Crystal oscillator: CL=6-9pF, R1=50K
4
R2023K/T
DC ELECTRICAL CHARACTERISTICS
(Unless otherwise specified: VSS=0V, VDD=3.0V, Topt=-40 to +85C, Crystal oscillator 32768Hz,CL=7pF,R1=50k) Symbol Item Pin Name Conditions Min. VIH "H" Input Voltage 0.8x SCL, SDA, VDD=1.7 to 5.5V VDD CLKC -0.3 VIL "L" Input Voltage IOH IOL1 IOL2 IOL3 IIL ICLKC IOZ "H" Output Current "L" Output Current 32KOUT 32KOUT INTRA INTRB SDA SCL CLKC SDA, INTRA , INTRB VDD VOH=VDD-0.5V VOL=0.4V 0.5 2.0 3.0 -1.0 0.30 -1 Typ. Max. 5.5 0.2x VDD -0.5 Unit
V mA
mA
Input Leakage Current Pull-down Resister Input Leakage Current Output Off-state Current Time Keeping Current
VI=5.5V or VSS VDD=5.5V VI=5.5V VO=5.5V or VSS VDD=5.5V VDD=3V, SCL=SDA=CLKC=0V 32KOUT=OFF OUTPUT=OPEN CGout=CDout=0pF *1) Topt=-30 to +70C
1.0 1.00 1
A A A
IDD
0.45
1.00
A
Supply Voltage VDD 1.45 1.60 1.75 V Monitoring Voltage "H" VDETL Supply Voltage VDD 1.15 1.30 1.45 V Topt=-30 to +70C Monitoring Voltage "L" *1) For time keeping current when outputting 32.768kHz from the 32KOUT pin, see "P.45 TYPICAL CHARACTERISTICS". For time keeping current when CGOUT, CDOUT is not equal to 0pF, see "P.30 *Adjustment of oscillation frequency".
VDETH
5
R2023K/T
AC ELECTRICAL CHARACTERISTICS
Unless otherwise specified: VSS=0V,Topt=-40 to +85C Input and Output Conditions: VIH=0.8xVDD,VIL=0.2xVDD,VOH=0.8xVDD,VOL=0.2xVDD,CL=50pF Sym Item CondiUnit VDD1.7V *1) -bol Tions Min. Typ. Max. fSCL SCL Clock Frequency 400 kHz tLOW SCL Clock Low Time 1.3 s tHIGH SCL Clock High Time 0.6 s tHD;STA Start Condition Hold Time 0.6 s tSU;STO Stop Condition Set Up Time 0.6 s tSU;STA Start Condition Set Up Time 0.6 s tSU;DAT Data Set Up Time 200 ns tHD;DAT Data Hold Time 0 ns tPL;DAT SDA "L" Stable Time 0.9 s After Falling of SCL tPZ;DAT SDA off Stable Time 0.9 s After Falling of SCL tR Rising Time of SCL and SDA 300 ns (input) tF Falling Time of SCL and SDA 300 ns (input) tSP Spike Width that can be 50 ns removed with Input Filter tRCV Recovery Time from Stop 62 s Condition to Start Condition *) For reading/writing timing, see "P.28 Interfacing with the CPU *Data Transmission under Special Conditions".
S Sr P
SCL tLOW tHIGH tHD;STA tSP
SDA(IN) tHD;STA tSU;DAT tHD;DAT tSU;STA
tSU;STO
SDA(OUT) tPL;DAT
S Sr
tPZ;DAT
P
Start Condition Repeated Start Condition
Stop Condition
6
R2023K/T
PACKAGE DIMENSIONS
*
R2023K
9 10
7 6
1PIN INDEX
0.05
12 1
4 3 2PIN INDEX 0.35 0.35 0.25 1.0Max
0.103
0.30.15
0.5
0.20.15
0.5
(BOTTOM VIEW) 0.170.1 0.270.15 2.00.1
unit: mm
2.00.1
7
R2023K/T
*
R2023T
0 to 10 6
2.90.2 10
2.80.2
4.00.2
1
5 0.5 (0.75)
0.13 -0.05
+0.1
0.1 0.20.1 0.15 M
0.1 -0.05
+0.1
0.850.15
0.550.2
unit: mm
8
R2023K/T
GENERAL DESCRIPTION
*
Interface with CPU
The R2023K/T is connected to the CPU by two signal lines, SCL and SDA, through which it reads and writes data from and to the CPU. Since the I/O pin of SDA is open drain, data interfacing with a CPU different supply voltage is possible by applying pull-up resistors on the circuit board. The maximum clock frequency of 400kHz (at VDD1.7v) of SCL enables data transfer in I2C bus fast mode.
*
Clock and Calendar Function
The R2023K/T reads and writes time data from and to the CPU in units ranging from seconds to the last two digits of the calendar year. The calendar year will automatically be identified as a leap year when its last two digits are a multiple of 4. Consequently, leap years up to the year 2099 can automatically be identified as such. *) The year 2000 is a leap year while the year 2100 is not a leap year.
*
Alarm Function
The R2023K/T incorporates the alarm interrupt circuit configured to generate interrupt signals to the CPU at preset times. The alarm interrupt circuit allows two types of alarm settings specified by the Alarm_W registers and the Alarm_D registers. The Alarm_W registers allow week, hour, and minute alarm settings including combinations of multiple day-of-week settings such as "Monday, Wednesday, and Friday" and "Saturday and Sunday". The Alarm_D registers allow hour and minute alarm settings. The Alarm_W outputs from INTRB pin, and the Alarm_D outputs from INTRA pin. Each alarm function can be checked from the CPU by using a polling function.
*
High-precision Oscillation Adjustment Function
The R2023K/T has built-in oscillation stabilization capacitors (CG and CD), which can be connected to an external crystal oscillator to configure an oscillation circuit. Two kinds of accuracy for this function are alternatives. To correct deviations in the oscillator frequency of the crystal, the oscillation adjustment circuit is configured to allow correction of a time count gain or loss (up to 1.5ppm or 0.5ppm at 25C) from the CPU. The maximum range is approximately 189ppm (or 63ppm) in increments of approximately 3ppm (or 1ppm). Such oscillation frequency adjustment in each system has the following advantages: * Allows timekeeping with much higher precision than conventional RTCs while using a crystal oscillator with a wide range of precision variations. * Corrects seasonal frequency deviations through seasonal oscillation adjustment. * Allows timekeeping with higher precision particularly with a temperature sensing function out of RTC, through oscillation adjustment in tune with temperature fluctuations.
*
Power-on Reset, Oscillation Halt Sensing Function and Supply Voltage Monitoring Function
The R2023K/T incorporates an oscillation halt sensing circuit equipped with internal registers configured to record any past oscillation halt. Power on reset function reset the control resisters when the system is powered on from 0V. At the same time, the fact is memorized to the resister as a flag, thereby identifying whether they are powered on from 0V or battery backed-up. The R2023K/T also incorporates a supply voltage monitoring circuit equipped with internal registers configured to record any drop in supply voltage below a certain threshold value. Supply voltage monitoring threshold settings can be selected between 1.6V and 1.3V through internal register settings. The sampling rate is normally 1s. The oscillation halt sensing circuit and the power-on reset flag are configured to confirm the established invalidation of time data in contrast to the supply voltage monitoring circuit intended to confirm the potential invalidation of time data. Further, the supply voltage monitoring circuit can be applied to battery supply voltage monitoring.
9
R2023K/T
*
Periodic Interrupt Function
The R2023K/T incorporates the periodic interrupt circuit configured to generate periodic interrupt signals aside from interrupt signals generated by the alarm interrupt circuit for output from the INTRA pin. Periodic interrupt signals have five selectable frequency settings of 2 Hz (once per 0.5 seconds), 1 Hz (once per 1 second), 1/60 Hz (once per 1 minute), 1/3600 Hz (once per 1 hour), and monthly (the first day of every month). Further, periodic interrupt signals also have two selectable waveforms, a normal pulse form (with a frequency of 2 Hz or 1 Hz) and special form adapted to interruption from the CPU in the level mode (with second, minute, hour, and month interrupts). The condition of periodic interrupt signals can be monitored with using a polling function.
*
32kHz Clock Output
The R2023K/T incorporates a 32-kHz clock circuit configured to generate clock pulses with the oscillation frequency of a 32.768kHz crystal oscillator for output from the 32KOUT pin. The 32KOUT pin is CMOS push-pull output and the output is enabled and disabled when the CLKC pin is held high, and low or open, respectively. The 32-kHz clock output can be disabled by certain register settings but cannot be disabled without manipulation of any two registers with different addresses to prevent disabling in such events as the runaway of the CPU. The 32-kHz clock circuit is enabled at power-on, when the CLKC pin is held high.
10
R2023K/T
Address Mapping
Address A3A2A1A0 0000 0001 0010 0011 0100 0101 0110 0111 Register Name Second Counter Minute Counter Hour Counter Day-of-week Counter Day-of-month Counter Month Counter and Century Bit Year Counter Oscillation Adjustment Register *3) Alarm_W (Minute Register) Alarm_W (Hour Register) Alarm_W (Day-of-week Register) Alarm_D (Minute Register) Alarm_D (Hour Register) Control Register 1 *3) Control Register 2 *3) D7 *2) 19 /20 Y80 DEV *4) D6 S40 M40 Y40 F6 D5 S20 M20 H20 P/ A D20 Y20 F5 D4 S10 M10 H10 D10 MO10 Y10 F4 D3 S8 M8 H8 D8 MO8 Y8 F3 Data D2 D1 S4 S2 M4 H4 W4 D4 MO4 Y4 F2 M2 H2 W2 D2 MO2 Y2 F1 D0 S1 M1 H1 W1 D1 MO1 Y1 F0
0 1 2 3 4 5 6 7
8 9 A
1000 1001 1010
WM40 WW6
WM20 WH20 WP/ A WW5
WM10 WH10 WW4
WM8 WH8 WW3
WM4 WH4 WW2
WM2 WH2 WW1
WM1 WH1 WW0
B C D E F
1011 1100 1101 1110 1111
WALE VDSL
DM40 DALE VDET
DM20 DH20 DP/ A 12 /24
XST
DM10 DH10 CLEN2 PON *5)
DM8 DH8 TEST
DM4 DH4 CT2
DM2 DH2 CT1 WAFG
DM1 DH1 CT0 DAFG
CLEN1 CTFG
Notes: * 1) All the data listed above accept both reading and writing. * 2) The data marked with "-" is invalid for writing and reset to 0 for reading. * 3) When the PON bit is set to 1 in Control Register 2, all the bits are reset to 0 in Oscillation Adjustment Register, Control Register 1 and Control Register 2 excluding the XST bit. * 4) When DEV=0, the oscillation adjustment circuit is configured to allow correction of a time count gain or loss up to 1.5ppm. When DEV=1, the oscillation adjustment circuit is configured to allow correction of a time count gain or loss up to or 0.5ppm. * 5) PON is a power-on-reset flag.
11
R2023K/T
Register Settings
*
Control Register 1 (ADDRESS Eh)
D7 D6 D5 D4 D3 D2 D1 D0 WALE DALE TEST CT2 CT1 CT0 (For Writing) 12 /24 CLEN2 WALE DALE TEST CT2 CT1 CT0 (For Reading) 12 /24 CLEN2 0 0 0 0 0 0 0 0 Default Settings *) *) Default settings: Default value means read / written values when the PON bit is set to "1" due to VDD power-on from 0 volts.
(1) WALE, DALEAlarm_W Enable Bit, Alarm_D Enable Bit
WALE,DALE 0 1 Description Disabling the alarm interrupt circuit (under the control of the settings of the Alarm_W registers and the Alarm_D registers). Enabling the alarm interrupt circuit (under the control of the settings of the Alarm_W registers and the Alarm_D registers) (Default)
(2) 12 /24
12 /24-hour Mode Selection Bit Description 12 /24 0 Selecting the 12-hour mode with a.m. and p.m. indications. (Default) 1 Selecting the 24-hour mode Setting the 12 /24 bit to 0 and 1 specifies the 12-hour mode and the 24-hour mode, respectively.
24-hour mode 12-hour mode 24-hour mode 00 12 (AM12) 12 01 01 (AM 1) 13 02 02 (AM 2) 14 03 03 (AM 3) 15 04 04 (AM 4) 16 05 05 (AM 5) 17 06 06 (AM 6) 18 07 07 (AM 7) 19 08 08 (AM 8) 20 09 09 (AM 9) 21 10 10 (AM10) 22 11 11 (AM11) 23 12 /24 bit should precede writing time data Setting the
12-hour mode 32 (PM12) 21 (PM 1) 22 (PM 2) 23 (PM 3) 24 (PM 4) 25 (PM 5) 26 (PM 6) 27 (PM 7) 28 (PM 8) 29 (PM 9) 30 (PM10) 31 (PM11)
(3) CLEN2
32kHz Clock Output Bit 2
Description CLEN2 0 Enabling the 32-kHz clock circuit (Default) 1 Disabling the 32-kHz clock circuit Setting the CLEN2 bit or the CLEN1 bit (D3 in the control register 2) to 0, and the CLKC pin to high specifies generating clock pulses with the oscillation frequency of the 32.768-kHz crystal oscillator for output from the 32KOUT pin. Conversely, setting both the CLEN1 and CLEN2 bit to 1 or CLKC pin to low specifies disabling ("L") such output.
(4) TEST
Test Bit
(Default)
TEST Description 0 Normal operation mode. 1 Test mode. The TEST bit is used only for testing in the factory and should normally be set to 0.
12
R2023K/T
(5) CT2, CT1, and CT0
CT2 CT1
Periodic Interrupt Selection Bits
CT0 Wave form mode Pulse Mode *1) Pulse Mode *1) Level Mode *2) Level Mode *2) Level Mode *2) Level Mode *2) Description Interrupt Cycle and Falling Timing OFF(H) Fixed at "L" 2Hz (Duty50%) 1Hz (Duty50%) Once per 1 second (Synchronized with second counter increment) Once per 1 minute (at 00 seconds of every minute) Once per hour (at 00 minutes and 00 seconds of every hour) Once per month (at 00 hours, 00 minutes, and 00 seconds of first day of every month) (Default)
0 0 0 0 1 1 1 1
0 0 1 1 0 0 1 1
0 1 0 1 0 1 0 1
* 1) Pulse Mode: 2-Hz and 1-Hz clock pulses are output in synchronization with the increment of the second counter as illustrated in the timing chart below.
CTFG Bit INTRA Pin Approx. 92s (Increment of second counter) Rewriting of the second counter
In the pulse mode, the increment of the second counter is delayed by approximately 92 s from the falling edge of clock pulses. Consequently, time readings immediately after the falling edge of clock pulses may appear to lag behind the time counts of the real-time clocks by approximately 1 second. Rewriting the second counter will reset the other time counters of less than 1 second, driving the INTRA pin low. * 2) Level Mode: Periodic interrupt signals are output with selectable interrupt cycle settings of 1 second, 1 minute, 1 hour, and 1 month. The increment of the second counter is synchronized with the falling edge of periodic interrupt signals. For example, periodic interrupt signals with an interrupt cycle setting of 1 second are output in synchronization with the increment of the second counter as illustrated in the timing chart below.
CTFG Bit INTRA Pin Setting CTFG bit to 0 (Increment of second counter) (Increment of second counter) Setting CTFG bit to 0 (Increment of second counter)
13
R2023K/T
*1), *2) When the oscillation adjustment circuit is used, the interrupt cycle will fluctuate once per 20sec. or 60sec. as follows: Pulse Mode: The "L" period of output pulses will increment or decrement by a maximum of 3.784 ms. For example, 1-Hz clock pulses will have a duty cycle of 50 0.3784%. Level Mode: A periodic interrupt cycle of 1 second will increment or decrement by a maximum of 3.784 ms.
*
Control Register 2 (Address Fh)
D7 D6 D5 D4 D3 D2 D1 D0 VDSL VDET PON CTFG WAFG DAFG (For Writing) CLEN1 XST PON VDSL VDET CTFG WAFG DAFG (For Reading) CLEN1 XST Indefinite 0 0 1 0 0 0 0 Default Settings *) *) Default settings: Default value means read / written values when the PON bit is set to "1" due to VDD power-on from 0 volts.
(1) VDSL
VDSL 0
VDD Supply Voltage Monitoring Threshold Selection Bit
(Default)
Description Selecting the VDD supply voltage monitoring threshold setting of 1.6v. 1 Selecting the VDD supply voltage monitoring threshold setting of 1.3v. The VDSL bit is intended to select the VDD supply voltage monitoring threshold settings.
(2) VDET
VDET 0
Supply Voltage Monitoring Result Indication Bit
Description Indicating supply voltage above the supply voltage monitoring (Default) threshold settings. 1 Indicating supply voltage below the supply voltage monitoring threshold settings. Once the VDET bit is set to 1, the supply voltage monitoring circuit will be disabled while the VDET bit will hold the setting of 1. The VDET bit accepts only the writing of 0, which restarts the supply voltage monitoring circuit. Conversely, setting the VDET bit to 1 causes no event.
(3) XST
Oscillation Halt Sensing Monitor Bit
Description XST 0 Sensing a halt of oscillation 1 Sensing a normal condition of oscillation The XST accepts the reading and writing of 0 and 1. The XST bit will be set to 0 when the oscillation halt sensing. The XST bit will hold 0 even after the restart of oscillation.
(4) PON
Power-on-reset Flag Bit
PON Description 0 Normal condition 1 Detecting VDD power-on -reset The PON bit is for sensing power-on reset condition.
(Default)
* The PON bit will be set to 1 when VDD power-on from 0 volts. The PON bit will hold the setting of 1 even after power-on. * When the PON bit is set to 1, all bits will be reset to 0, in the Oscillation Adjustment Register, Control Register 1, and Control Register 2, except XST and PON. As a result, INTR pin stops outputting. * The PON bit accepts only the writing of 0. Conversely, setting the PON bit to 1 causes no event. 14
R2023K/T
(5) CLEN1
32kHz Clock Output Bit 1
Description CLEN1 0 Enabling the 32-kHz clock circuit (Default) 1 Disabling the 32-kHz clock circuit Setting the CLEN1 bit or the CLEN2 bit (D4 in the control register 1) to 0, and the CLKC pin to high specifies generating clock pulses with the oscillation frequency of the 32.768-kHz crystal oscillator for output from the 32KOUT pin. Conversely, setting both the CLEN1 and CLEN2 bit to 1 or CLKC pin to low specifies disabling ("L") such output.
(6) CTFG
Periodic Interrupt Flag Bit
CTFG Description 0 Periodic interrupt output = "H" (Default) 1 Periodic interrupt output = "L" The CTFG bit is set to 1 when the periodic interrupt signals are output from the INTRA pin ("L"). The CTFG bit accepts only the writing of 0 in the level mode, which disables ("H") the INTRA pin until it is enabled ("L") again in the next interrupt cycle. Conversely, setting the CTFG bit to 1 causes no event.
(7) WAFG,DAFG
Alarm_W Flag Bit and Alarm_D Flag Bit
WAFG,DAFG Description 0 Indicating a mismatch between current time and preset alarm time (Default) 1 Indicating a match between current time and preset alarm time The WAFG and DAFG bits are valid only when the WALE and DALE have the setting of 1, which is caused approximately 61s after any match between current time and preset alarm time specified by the Alarm_W registers and the Alarm_D registers. The WAFG (DAFG) bit accepts only the writing of 0. INTRA ( INTRB ) pin outputs off ("H") when this bit is set to 0. And INTRA ( INTRB ) pin outputs "L" again at the next preset alarm time. Conversely, setting the WAFG and DAFG bits to 1 causes no event. The WAFG and DAFG bits will have the reading of 0 when the alarm interrupt circuit is disabled with the WALE and DALE bits set to 0. The settings of the WAFG and DAFG bits are synchronized with the output of the INTRA ( INTRB ) pin as shown in the timing chart below.
Approx. 61s WAFG(DAFG) Bit INTRB (INTRA) Pin Writing of 0 to WAFG(DAFG) bit (Match between current time and preset alarm time) (Match between current time and preset alarm time) Writing of 0 to WAFG(DAFG) bit (Match between current time and preset alarm time) Approx. 61s
15
R2023K/T
*
Time Counter (Address 0-2h)
Second Counter (Address 0h) D7 D6 D5 S40 S20 0 S40 S20 0 Indefi Indefi nite nite Minute Counter (Address 1h) D7 D6 D5 M40 M20 0 M40 M20 0 Indefi Indefi nite nite
D4 S10 S10 Indefi nite
D3 S8 S8 Indefi nite
D2 S4 S4 Indefi nite
D1 S2 S2 Indefi nite
D0 S1 S1 Indefi nite
(For Writing) (For Reading) Default Settings *)
D4 M10 M10 Indefi nite
D3 M8 M8 Indefi nite
D2 M4 M4 Indefi nite
D1 M2 M2 Indefi nite
D0 M1 M1 Indefi nite
(For Writing) (For Reading) Default Settings *)
Hour Counter (Address 2h) D7 D6 D5 D4 D3 D2 D1 D0 H10 H8 H4 H2 H1 (For Writing) P/ A or H20 H10 H8 H4 H2 H1 (For Reading) 0 0 P/ A or H20 0 0 Indefi Indefi Indefi Indefi Indefi Indefi Default Settings *) nite nite nite nite nite nite *) Default settings: Default value means read / written values when the PON bit is set to "1" due to VDD power-on from 0 volts. * Time digit display (BCD format) as follows: The second digits range from 00 to 59 and are carried to the minute digit in transition from 59 to 00. The minute digits range from 00 to 59 and are carried to the hour digits in transition from 59 to 00. The hour digits range as shown in "P12 * Control Register 1 (ADDRESS Eh) (2) 12 /24: 12 /24-hour Mode Selection Bit" and are carried to the day-of-month and day-of-week digits in transition from PM11 to AM12 or from 23 to 00. * Any writing to the second counter resets divider units of less than 1 second. * Any carry from lower digits with the writing of non-existent time may cause the time counters to malfunction. Therefore, such incorrect writing should be replaced with the writing of existent time data.
*
Day-of-week Counter (Address 3h)
D2 D1 D0 W4 W2 W1 (For Writing) W4 W2 W1 (For Reading) Indefi Indefi Indefi Default Settings *) nite nite nite *) Default settings: Default value means read / written values when the PON bit is set to "1" due to VDD power-on from 0 volts. * The day-of-week counter is incremented by 1 when the day-of-week digits are carried to the day-of-month digits. * Day-of-week display (incremented in septimal notation): (W4, W2, W1) = (0, 0, 0) (0, 0, 1)...(1, 1, 0) (0, 0, 0) D7 0 0 D6 0 0 D5 0 0 D4 0 0 D3 0 0
16
R2023K/T
* Correspondences between days of the week and the day-of-week digits are user-definable (e.g. Sunday = 0, 0, 0) * The writing of (1, 1, 1) to (W4, W2, W1) is prohibited except when days of the week are unused.
*
Calendar Counter (Address 4-6h)
Day-of-month Counter (Address 4h) D7 D6 D5 D20 0 0 D20 0 0 Indefi nite
D4 D10 D10 Indefi nite
D3 D8 D8 Indefi nite
D2 D4 D4 Indefi nite
D1 D2 D2 Indefi nite
D0 D1 D1 Indefi nite
(For Writing) (For Reading) Default Settings *)
Month Counter + Century Bit (Address 5h) D7 D6 D5 D4 MO10 19 /20 0 0 MO10 19 /20 Indefi 0 0 Indefi nite nite
D3 MO8 MO8 Indefi nite
D2 MO4 MO4 Indefi nite
D1 MO2 MO2 Indefi nite
D0 MO1 MO1 Indefi nite
(For Writing) (For Reading) Default Settings *)
Year Counter (Address 6h) D7 D6 D5 D4 D3 D2 D1 D0 Y80 Y40 Y20 Y10 Y8 Y4 Y2 Y1 (For Writing) Y80 Y40 Y20 Y10 Y8 Y4 Y2 Y1 (For Reading) Indefi Indefi Indefi Indefi Indefi Indefi Indefi Indefi Default Settings *) nite nite nite nite nite nite nite nite *) Default settings: Default value means read / written values when the PON bit is set to "1" due to VDD power-on from 0 volts. * The calendar counters are configured to display the calendar digits in BCD format by using the automatic calendar function as follows: The day-of-month digits (D20 to D1) range from 1 to 31 for January, March, May, July, August, October, and December; from 1 to 30 for April, June, September, and November; from 1 to 29 for February in leap years; from 1 to 28 for February in ordinary years. The day-of-month digits are carried to the month digits in reversion from the last day of the month to 1. The month digits (MO10 to MO1) range from 1 to 12 and are carried to the year digits in reversion from 12 to 1. The year digits (Y80 to Y1) range from 00 to 99 (00, 04, 08, ..., 92, and 96 in leap years) and are carried to the 19 /20 digits in reversion from 99 to 00. The 19 /20 digits cycle between 0 and 1 in reversion from 99 to 00 in the year digits. * Any carry from lower digits with the writing of non-existent calendar data may cause the calendar counters to malfunction. Therefore, such incorrect writing should be replaced with the writing of existent calendar data.
17
R2023K/T
*
Oscillation Adjustment Register (Address 7h)
D7 D6 D5 D4 D3 D2 D1 D0 DEV F6 F5 F4 F3 F2 F1 F0 (For Writing) DEV F6 F5 F4 F3 F2 F1 F0 (For Reading) 0 0 0 0 0 0 0 0 Default Settings *) *) Default settings: Default value means read / written values when the PON bit is set to "1" due to VDD power-on from 0 volts. DEV bit When DEV is set to 0, the Oscillation Adjustment Circuit operates 00, 20, 40 seconds. When DEV is set to 1, the Oscillation Adjustment Circuit operates 00 seconds.
F6 to F0 bits The Oscillation Adjustment Circuit is configured to change time counts of 1 second on the basis of the settings of the Oscillation Adjustment Register at the timing set by DEV. * The Oscillation Adjustment Circuit will not operate with the same timing (00, 20, or 40 seconds) as the timing of writing to the Oscillation Adjustment Register. * The F6 bit setting of 0 causes an increment of time counts by ((F5, F4, F3, F2, F1, F0) - 1) x 2. The F6 bit setting of 1 causes a decrement of time counts by (( F5,F4,F3,F2,F1,F0 ) + 1) x 2. The settings of "*, 0, 0, 0, 0, 0, *" ("*" representing either "0" or "1") in the F6, F5, F4, F3, F2, F1, and F0 bits cause neither an increment nor decrement of time counts. Example: If (DEV, F6, F5, F4, F3, F2, F1, F0) is set to (0, 0, 0, 0, 0, 1, 1, 1), when the second digits read 00, 20, or 40, an increment of the current time counts of 32768 + (7 - 1) x 2 to 32780 (a current time count loss). If (DEV, F6, F5, F4, F3, F2, F1, F0) is set to (0, 0, 0, 0, 0, 0, 0, 1), when the second digits read 00, 20, 40, neither an increment nor a decrement of the current time counts of 32768. If (DEV, F6, F5, F4, F3, F2, F1, F0) is set to (1, 1, 1, 1, 1, 1, 1, 0), when the second digits read 00, a decrement of the current time counts of 32768 + (- 2) x 2 to 32764 (a current time count gain). An increase of two clock pulses once per 20 seconds causes a time count loss of approximately 3 ppm (2 / (32768 x 20 = 3.051 ppm). Conversely, a decrease of two clock pulses once per 20 seconds causes a time count gain of 3 ppm. Consequently, when DEV is set to "0", deviations in time counts can be corrected with a precision of 1.5 ppm. In the same way, when DEV is set to "1", deviations in time counts can be corrected with a precision of 0.5 ppm. Note that the oscillation adjustment circuit is configured to correct deviations in time counts and not the oscillation frequency of the 32.768-kHz clock pulses. For further details, see "P33 Configuration of Oscillation Circuit and Correction of Time Count Deviations * Oscillation Adjustment Circuit".
18
R2023K/T
Alarm_W Registers (Address 8-Ah)
Alarm_W Minute Register (Address 8h) D7 D6 D5 D4 WM40 WM20 WM10 0 WM40 WM20 WM10 0 Indefi Indefi Indefi nite nite nite Alarm_W Hour Register (Address 9h) D7 D6 D5 D4 WH20 WH10 WP/ A WH10 0 0 WH20 WP/ A 0 0 Indefi Indefi nite nite
D3 WM8 WM8 Indefi nite
D2 WM4 WM4 Indefi nite
D1 WM2 WM2 Indefi nite
D0 WM1 WM1 Indefi nite
(For Writing) (For Reading) Default Settings *)
D3 WH8 WH8 Indefi nite
D2 WH4 WH4 Indefi nite
D1 WH2 WH2 Indefi nite
D0 WH1 WH1 Indefi nite
(For Writing) (For Reading) Default Settings *)
Alarm_W Day-of-week Register (Address Ah) D7 D6 D5 D4 D3 D2 D1 D0 WW6 WW5 WW4 WW3 WW2 WW1 WW0 (For Writing) 0 WW6 WW5 WW4 WW3 WW2 WW1 WW0 (For Reading) 0 Indefi Indefi Indefi Indefi Indefi Indefi Indefi Default Settings *) nite nite nite nite nite nite nite *) Default settings: Default value means read / written values when the PON bit is set to "1" due to VDD power-on from 0 volts. * The D5 bit of the Alarm_W Hour Register represents WP/ A when the 12-hour mode is selected (0 for a.m. and 1 for p.m.) and WH20 when the 24-hour mode is selected (tens in the hour digits). * The Alarm_W Registers should not have any non-existent alarm time settings. (Note that any mismatch between current time and preset alarm time specified by the Alarm_W registers may disable the alarm interrupt circuit.) * When the 12-hour mode is selected, the hour digits read 12 and 32 for 0 a.m. and 0 p.m., respectively. (See "P12 *Control Register 1 (ADDRESS Eh) (2) 12 /24: 12 /24-hour Mode Selection Bit") * WW0 to WW6 correspond to W4, W2, and W1 of the day-of-week counter with settings ranging from (0, 0, 0) to (1, 1, 0). * WW0 to WW6 with respective settings of 0 disable the outputs of the Alarm_W Registers.
19
R2023K/T
Example of Alarm Time Setting Alarm Day-of-week Preset alarm Sun. Mon. Tue. Wed. Th. time
Fri.
Sat.
12-hour mode 1 11 1 0 h0 m h rm in r. . in . .
1 0 h r .
24-hour mode 1 1 1 h 0 mi r. m n. in .
00:00 a.m. on all 1 20 0 00 0 days 01:30 a.m. on all 1 1 1 1 1 1 1 0 13 0 01 3 days 11:59 a.m. on all 1 1 1 1 1 1 1 1 15 9 11 5 days 00:00 p.m. on Mon. 0 1 1 1 1 1 0 3 20 0 12 0 to Fri. 01:30 p.m. on Sun. 1 0 0 0 0 0 0 2 13 0 13 3 11:59 p.m. 0 1 0 1 0 1 0 3 15 9 23 5 on Mon. ,Wed., and Fri. Note that the correspondence between WW0 to WW6 and the days of the week shown in the above table is only an example and not mandatory.
WW 0 1
WW 1 1
WW 2 1
WW 3 1
WW 4 1
WW 5 1
WW 6 1
0 0 9 0 0 9
*
Alarm_D Register (Address B-Ch)
Alarm_D Minute Register (Address Bh) D7 D6 D5 D4 DM40 DM20 DM10 0 DM40 DM20 DM10 Indefinit Indefinit Indefinit 0
e e e
D3 DM8 DM8
Indefinit e
D2 DM4 DM4
Indefinit e
D1 DM2 DM2
Indefinit e
D0 DM1 DM1
Indefinit e
(For Writing) (For Reading) Default Settings *)
Alarm_D Hour Register (Address Ch) D7 D6 D5 D4 D3 D2 D1 D0 DH20 DH10 DH8 DH4 DH2 DH1 (For Writing) DP/ A DH10 DH8 DH4 DH2 DH1 (For Reading) 0 0 DH20 DP/ A 0 0 Indefi Indefi Indefi Indefi Indefi Indefi Default Settings *) nite nite nite nite nite nite *) Default settings: Default value means read / written values when the PON bit is set to "1" due to VDD power-on from 0 volts. * The D5 bit represents DP/ A when the 12-hour mode is selected (0 for a.m. and 1 for p.m.) and DH20 when the 24-hour mode is selected (tens in the hour digits). * The Alarm_D registers should not have any non-existent alarm time settings. (Note that any mismatch between current time and preset alarm time specified by the Alarm_D registers may disable the alarm interrupt circuit.) * When the 12-hour mode is selected, the hour digits read 12 and 32 for 0a.m. and 0p.m., respectively. (See "P12 *Control Register 1 (ADDRESS Eh) (2) 12 /24: 12 /24-hour Mode Selection Bit")
20
R2023K/T
Interfacing with the CPU
The R2023K/T employs the I2C-Bus system to be connected to the CPU via 2-wires. Connection and system of I2C-Bus are described in the following sections.
*
Connection of I2C-Bus
2-wires, SCL and SDA pins that are connected to I2C-Bus are used for transmit clock pulses and data respectively. All ICs that are connected to these lines are designed that will not be clamped when a voltage beyond supply voltage is applied to input or output pins. Open drain pins are used for output. This construction allows communication of signals between ICs with different supply voltages by adding a pull-up resistor to each signal line as shown in the figure below. Each IC is designed not to affect SCL and SDA signal lines when power to each of these is turned off separately.
VDD1 VDD2 VDD3 VDD4 Rp Rp
* For data interface, the following conditions must be met: VCC4VCC1 VCC4VCC2 VCC4VCC3 * When the master is one, the micro-controller is ready for driving SCL to "H" and Rp of SCL may not be required.
SCL SDA
MicroController
R2023K/T
Other Peripheral Device
Cautions on determining Rp resistance, (1) Dropping voltage at Rp due to sum of input current or output current at off conditions on each IC pin connected to the I2C-Bus shall be adequately small. (2) Rising time of each signal be kept short even when all capacity of the bus is driven. (3) Current consumed in I2C-Bus is small compared to the consumption current permitted for the entire system. When all ICs connected to I2C-Bus are CMOS type, condition (1) may usually be ignored since input current and off-state output current is extremely small for the many CMOS type ICs. Thus the maximum resistance of Rp may be determined based on (2), while the minimum on (3) in most cases. In actual cases a resistor may be place between the bus and input/output pins of each IC to improve noise margins in which case the Rp minimum value may be determined by the resistance. Consumption current in the bus to review (3) above may be expressed by the formula below: Bus consumption current (Sum of input current and off state output current of all devices in standby mode ) x Bus standby duration Bus stand-by duration + the Bus operation duration + Supply voltage x Bus operation duration x 2 Rp resistance x 2 x (Bus stand-by duration + bus operation duration)
+ Supply voltage x Bus capacity x Charging/Discharging times per unit time Operation of "x 2" in the second member denominator in the above formula is derived from assumption that "L" duration of SDA and SCL pins are the half of bus operation duration. "x 2" in the numerator of the same member 21
R2023K/T
is because there are two pins of SDA and SCL. The third member, (charging/discharging times per unit time) means number of transition from "H" to "L" of the signal line.
Calculation example is shown below: Pull-up resistor (Rp) = 10k, Bus capacity = 50pF(both for SCL, SDA), VDD=3V, In a system with sum of input current and off-state output current of each pin = 0.1A, I2C-Bus is used for 10ms every second while the rest of 990ms in the stand-by mode, In this mode, number of transitions of the SCL pin from "H" to "L" state is 100 while SDA 50, every second. Bus consumption current 0.1Ax990msec 990msec + 10msec 3V x 10msec x 2 10K x 2 x (990msec + 10msec)
+
+ 3V x 50pF x (100 + 50) 0.099A + 3.0A + 0.0225A 3.12A Generally, the second member of the above formula is larger enough than the first and the third members bus consumption current may be determined by the second member is many cases.
22
R2023K/T
*
Transmission System of I2C-Bus
(1) Start Condition and Stop Condition
In I2C-Bus, SDA must be kept at a certain state while SCL is at the "H" state during data transmission as shown below.
SCL
SDA tHD;DAT
tSU;DAT
The SCL and SDA pins are at the "H" level when no data transmission is made. Changing the SDA from "H" to "L" when the SCL and the SDA are "H" activates the Start Condition and access is started. Changing the SDA from "L" to "H" when the SCL is "H" activates Stop Condition and accessing stopped. Generation of Start and Stop Conditions are always made by the master (see the figure below).
Start Condition SCL Stop Condition
SDA
tHD;STA
tSU;STO
(2) Data transmission and its acknowledge
After Start condition is entered, data is transmitted by 1byte (8bits). Any bytes of data may be serially transmitted. The receiving side will send an acknowledge signal to the transmission side each time 8bit data is transmitted. The acknowledge signal is sent immediately after falling to "L" of SCL 8bit clock pulses of data is transmitted, by releasing the SDA by the transmission side that has asserted the bus at that time and by turning SDA to "L" by receiving side. When transmission of 1byte data next to preceding 1byte of data is received the receiving side releases the SDA pin at falling edge of the SCL 9bit of clock pulses or when the receiving side switches to the transmission side it starts data transmission. When the master is receiving side, it generates no acknowledge signal after last 1byte of data from the slave to tell the transmitter that data transmission has completed. The slave side (transmission side) continues to release the SDA pin so that the master will be able to generate Stop Condition, after falling edge of the SCL 9bit of clock pulses.
SCL from the master SDA from the transmission side SDA from the receiving side Start Condition Acknowledge signal
1
2
8
9
23
R2023K/T
(3) Data Transmission Format in I2C-Bus
I2C-Bus has no chip enable signal line. In place of it, each device has a 7bit Slave Address allocated. The first 1byte is allocated to this 7bit address and to the command (R/W) for which data transmission direction is designated by the data transmission thereafter. 7bit address is sequentially transmitted from the MSB and 2 and after bytes are read, when 8bit is "H" and when write "L". The Slave Address of the R2023K/T is specified at (0110010). At the end of data transmission / receiving, Stop Condition is generated to complete transmission. However, if start condition is generated without generating Stop Condition, Repeated Start Condition is met and transmission / receiving data may be continue by setting the Slave Address again. Use this procedure when the transmission direction needs to be change during one transmission.
Data is written to the slave from the master S Slave Address (0110010) When data is read from the slave immediately after 7bit addressing from the master S Slave Address (0110010) When the transmission direction is to be changed during transmission. 0A R/W=0(Write) 1A R/W=1(Read) Data A Data /A P Data A Data AP
Inform read has been completed by not generate an acknowledge signal to the slave side.
S
Slave Address
(0110010)
0A R/W=0(Write) A
Data
A Sr
Salve Address
1
(0110010) Data /A P
R/W=1(Read)
A
Data
Inform read has been completed by not generate an acknowledge signal to the slave side.
Master to slave S Start Condition
P
Slave to master Stop Condition
A
Sr
A
/A Acknowledge Signal
Repeated Start Condition
24
R2023K/T
(4) Data Transmission Write Format in the R2023K/T
Although the I2C-Bus standard defines a transmission format for the slave allocated for each IC, transmission method of address information in IC is not defined. The R2023K/T transmits data the internal address pointer (4bit) and the Transmission Format Register (4bit) at the 1byte next to one which transmitted a Slave Address and a write command. For write operation only one transmission format is available and (0000) is set to the Transmission Format Register. The 3byte transmits data to the address specified by the internal address pointer written to the 2byte. Internal address pointer setting are automatically incremented for 4byte and after. Note that when the internal address pointer is Fh, it will change to 0h on transmitting the next byte.
Example of data writing (When writing to internal address Eh to Fh)
R/W=0(Write) S01100100A11100000A Slave Address (0110010) Address Transmission Pointer Format Eh Register
0h
Data Writing of data to the internal address Eh
A
Data Writing of data to the internal address Fh
AP
Master to slave S A Start Condition A /A Acknowledge signal P
Slave to master Stop Condition
25
R2023K/T
(5) Data transmission read format of the R2023K/T
The R2023K/T allows the following three read out method of data an internal register. The first method to reading data from the internal register is to specify an internal address by setting the internal address pointer and the transmission format register described P25 (4), generate the Repeated Start Condition (See P24 (3)) to change the data transmission direction to perform reading. The internal address pointer is set to Fh when the Stop Condition is met. Therefore, this method of reading allows no insertion of Stop Condition before the Repeated Start Condition. Set 0h to the Transmission Format Register when this method used.
Example 1 of Data Read (when data is read from 2h to 4h)
R/W=0(Write) Repeated Start Condition R/W=1(Read)
S 0 1 1 0 0 1 0 0 A 0 0 1 0 0 0 0 0 A Sr 0 1 1 0 0 1 0 1 A Slave Address (0110010) Address Transmission Pointer2h Format
Register0h
Slave Address (0110010)
Data Reading of data from the internal address 2h
A
Data Reading of data from the internal address 3h
A
Data Reading of data from the internal address 4h
/A P
Master to slave S A Start Condition A /A Acknowledge signal Sr
Slave to master Repeated Start Condition P Stop Condition
26
R2023K/T
The second method to reading data from the internal register is to start reading immediately after writing to the Internal Address Pointer and the Transmission Format Register. Although this method is not based on I2C-Bus standard in a strict sense it still effective to shorten read time to ease load to the master. Set 4h to the transmission format register when this method used.
Example 2 of data read (when data is read from internal addresses Eh to 1h)
R/W=0(Write) S01100100A11100100A Slave Address (0110010) Address Transmission Pointer Format Register4h Eh Data Reading of data from the internal address Eh A
Data Reading of data from the internal address Fh
A
Data Reading of data from the internal address 0h
A
Data Reading of data from the internal address 1h
/A P
Master to slave S A Start Condition A /A Acknowledge Signal
Slave to Master P Stop Condition
The third method to reading data from the internal register is to start reading immediately after writing to the Slave Address and R/W bit. Since the Internal Address Pointer is set to Fh by default as described in the first method, this method is only effective when reading is started from the Internal Address Fh.
Example 3 of data read (when data is read from internal addresses Fh to 3h)
R/W=1(Read) S01100101A Slave Address (0110010) Data Reading of data from the Internal Address Fh A Data Reading of data from the Internal Address 0h A
Data Reading of data from the Internal Address 1h
A
Data Reading of data from the Internal Address 2h
A
Data Reading of data from the Internal Address 3h
/A P
Master to slave S A Start Condition A /A Acknowledge Signal
Slave to master P Stop Condition
27
R2023K/T
*
Data Transmission under Special Condition
The R2023K/T holds the clock tentatively for duration from Start Condition to avoid invalid read or write clock on carrying clock. When clock carried during this period, which will be adjusted within approx. 61s from Stop Condition. To prevent invalid read or write, clock and calendar data shall be made during one transmission operation (from Start Condition to Stop Condition). When 0.5 to 1.0 second elapses after Start Condition, any access to the R2023K/T is automatically released to release tentative hold of the clock, and access from the CPU is forced to be terminated (The same action as made Stop Condition is received: automatic resume function from I2C-Bus interface). Therefore, one access must be complete within 0.5 seconds. The automatic resume function prevents delay in clock even if SCL is stopped from sudden failure of the system during clock read operation. Also a second Start Condition after the first Start Condition and before the Stop Condition is regarded "Repeated Start Condition". Therefore, when 0.5 to 1.0 seconds passed after the first Start Condition, an access to the R2023K/T is automatically released. If access is tried after automatic resume function is activated, no acknowledge signal will be output for writing while FFh will be output for reading. The user shall always be able to access the real-time clock as long as three conditions are met. No Stop Condition shall be generated until clock and calendar data read/write is started and completed. One cycle read/write operation shall be complete within 0.5 seconds. Do not make Start Condition within 61s from Stop Condition. When clock is carried during the access, which will be adjusted within approx. 61s from Stop Condition. Bad example of reading from seconds to hours (invalid read) (Start Condition) (Read of seconds) (Read of minutes) (Stop Condition) (Start Condition) (Read of hour) (Stop Condition) Assuming read was started at 05:59:59 P.M. and while reading seconds and minutes the time advanced to 06:00:00 P.M. At this time second digit is hold so read the read as 05:59:59. Then the R2023K/T confirms (Stop Condition) and carries second digit being hold and the time change to 06:00:00 P.M. Then, when the hour digit is read, it changes to 6. The wrong results of 06:59:59 will be read.
28
R2023K/T
Configuration of Oscillation Circuit and Correction of Time Count Deviations
*
Configuration of Oscillation Circuit
Typical externally-equipped element X'tal : 32.768kHz (R1=50k typ) (CL=6pF to 9pF) Standard values of internal elements CG,CD 10pF typ
OSCIN Oscillator CG Circuit OSCOUT CD
32kHz
A
The oscillation circuit is driven at a constant voltage of approximately 1.2 volts relative to the level of the VSS pin input. As such, it is configured to generate an oscillating waveform with a peak-to-peak voltage on the order of 1.1 volts on the positive side of the VSS pin input. < Considerations in Handling quartz crystal unit > Generally, quartz crystal units have basic characteristics including an equivalent series resistance (R1) indicating the ease of their oscillation and a load capacitance (CL) indicating the degree of their center frequency. Particularly, quartz crystal units intended for use in the R2023K/T are recommended to have a typical R1 value of 50k and a typical CL value of 6 to 9pF. To confirm these recommended values, contact the manufacturers of quartz crystal units intended for use in these particular models. < Considerations in Installing Components around the Oscillation Circuit > 1) Install the quartz crystal unit in the closest possible vicinity to the real-time clock ICs. 2) Avoid laying any signal lines or power lines in the vicinity of the oscillation circuit (particularly in the area marked "A" in the above figure). 3) Apply the highest possible insulation resistance between the OSCIN and OSCOUT pins and the printed circuit board. 4) Avoid using any long parallel lines to wire the OSCIN and OSCOUT pins. 5) Take extreme care not to cause condensation, which leads to various problems such as oscillation halt. < Other Relevant Considerations > 1) We cannot recommend connecting the external input of 32.768-kHz clock pulses to the OSCIN pin. 2) To maintain stable characteristics of the quartz crystal unit, avoid driving any other IC through 32.768-kHz clock pulses output from the OSCOUT pin.
29
R2023K/T
*
Measurement of Oscillation Frequency
VDD CLKC OSCIN OSCOUT 32KOUT VSS 32768Hz Frequency Counter
* 1) The R2023K/T is configured to generate 32.768-kHz clock pulses for output from the 32KOUT pin. * 2) A frequency counter with 6 (more preferably 7) or more digits on the order of 1ppm is recommended for use in the measurement of the oscillation frequency of the oscillation circuit.
*
Adjustment of Oscillation frequency
The oscillation frequency of the oscillation circuit can be adjusted by varying procedures depending on the usage of Model R2023K/T in the system into which they are to be built and on the allowable degree of time count errors. The flow chart below serves as a guide to selecting an optimum oscillation frequency adjustment procedure for the relevant system.
Start
Use 32-kHz clock output? YES
YES NO Allowable time count precision on order of oscillation frequency variations of crystal oscillator (*1) plus NO frequency variations of RTC (*2)? (*3) YES
Course (A)
Course (B)
Use 32-kHz clock output without regard to its frequency precision Course (C) NO YES Allowable time count precision on order of oscillation frequency variations of crystal oscillator (*1) plus NO frequency variations of RTC (*2)? (*3)
Course (D)
* 1) Generally, quartz crystal units for commercial use are classified in terms of their center frequency depending on their load capacitance (CL) and further divided into ranks on the order of 10, 20, and 50ppm depending on the degree of their oscillation frequency variations. * 2) Basically, Model R2023K/T is configured to cause frequency variations on the order of 5 to 10ppm at 25C. * 3) Time count precision as referred to in the above flow chart is applicable to normal temperature and actually affected by the temperature characteristics and other properties of quartz crystal units.
30
R2023K/T
Course (A) When the time count precision of each RTC is not to be adjusted, the quartz crystal unit intended for use in that RTC may have any CL value requiring no presetting. The quartz crystal unit may be subject to frequency variations which are selectable within the allowable range of time count precision. Several quartz crystal units and RTCs should be used to find the center frequency of the quartz crystal units by the method described in "P30 * Measurement of Oscillation Frequency" and then calculate an appropriate oscillation adjustment value by the method described in "P33 * Oscillation Adjustment Circuit" for writing this value to the R2023K/T. Course (B) When the time count precision of each RTC is to be adjusted within the oscillation frequency variations of the quartz crystal unit plus the frequency variations of the real-time clock ICs, it becomes necessary to correct deviations in the time count of each RTC by the method described in " P30 * Oscillation Adjustment Circuit". Such oscillation adjustment provides quartz crystal units with a wider range of allowable settings of their oscillation frequency variations and their CL values. The real-time clock IC and the quartz crystal unit intended for use in that real-time clock IC should be used to find the center frequency of the quartz crystal unit by the method described in " P30 * Measurement of Oscillation Frequency" and then confirm the center frequency thus found to fall within the range adjustable by the oscillation adjustment circuit before adjusting the oscillation frequency of the oscillation circuit. At normal temperature, the oscillation frequency of the oscillator circuit can be adjusted by up to approximately 0.5ppm. Course (C) Course (C) together with Course (D) requires adjusting the time count precision of each RTC as well as the frequency of 32.768-kHz clock pulses output from the 32KOUT pin. Normally, the oscillation frequency of the crystal oscillator intended for use in the RTCs should be adjusted by adjusting the oscillation stabilizing capacitors CG and CD connected to both ends of the crystal oscillator. The R2023K/T, which incorporate the CG and the CD, require adjusting the oscillation frequency of the crystal oscillator through its CL value. Generally, the relationship between the CL value and the CG and CD values can be represented by the following equation: CL = (CG x CD)/(CG + CD) + CS where "CS" represents the floating capacity of the printed circuit board. The crystal oscillator intended for use in the R2023K/T is recommended to have the CL value on the order of 6 to 9pF. Its oscillation frequency should be measured by the method described in " P.30 * Measurement of Oscillation Frequency ". Any crystal oscillator found to have an excessively high or low oscillation frequency (causing a time count gain or loss, respectively) should be replaced with another one having a smaller and greater CL value, respectively until another one having an optimum CL value is selected. In this case, the bit settings disabling the oscillation adjustment circuit (see " P.33 * Oscillation Adjustment Circuit") should be written to the oscillation adjustment register. Incidentally, the high oscillation frequency of the crystal oscillator can also be adjusted by adding an external oscillation stabilization capacitor CGOUT or/and CDOUT as illustrated in the diagram below.
*1) The CGOUT or/and CDOUT should have a capacitance ranging from 0 to 6 pF.
OSCIN Oscillator Circuit CG RD CD 32kHz OSCOUT CDOUT CGOUT
31
R2023K/T
However, if adding CGOUT and/or CDOUT, Time keeping Voltage and Current will be worse, and it will be hard to oscillate. For reference, the data of Time keeping voltage and current when adding CGOUT=CDOUT=5pF are shown in the table below. (Topt=-40 to 85C, VSS=0v) PIN Item Condition Min. TYP. MAX. UNITS Vclk Time Keeping CGout=CDout=5pF 1.15 5.5 V Voltage IDD Time Keeping VDD=3V, Current SCL, SDA, CLKC=0V 0.55 1.20 A 32KOUT=OPEN OUTPUT=OPEN CGout=CDout=0pF Course (D) It is necessary to select the crystal oscillator in the same manner as in Course (C) as well as correct errors in the time count of each RTC in the same manner as in Course (B) by the method described in " P.33 * Oscillation Adjustment Circuit ".
32
R2023K/T
*
Oscillation Adjustment Circuit
The oscillation adjustment circuit can be used to correct a time count gain or loss with high precision by varying the number of 1-second clock pulses once per 20 seconds or 60 seconds. When DEV bit in the Oscillation Adjustment Register is set to 0, R2023K/T varies number of 1-second clock pulses once per 20 seconds. When DEV bit is set to 1, R2023K/T varies number of 1-second clock pulses once per 60 seconds. The oscillation adjustment circuit can be disabled by writing the settings of "*, 0, 0, 0, 0, 0, *" ("*" representing "0" or "1") to the F6, F5, F4, F3, F2, F1, and F0 bits in the oscillation adjustment circuit. Conversely, when such oscillation adjustment is to be made, an appropriate oscillation adjustment value can be calculated by the equation below for writing to the oscillation adjustment circuit.
(1) When Oscillation Frequency (* 1) Is Higher Than Target Frequency (* 2) (Causing Time Count Gain)
When DEV=0: Oscillation adjustment value (*3) = (Oscillation frequency - Target Frequency + 0.1) Oscillation frequency x 3.051 x 10-6 (Oscillation Frequency - Target Frequency) x 10 + 1 When DEV=1: Oscillation adjustment value (*3) = (Oscillation frequency - Target Frequency + 0.0333) Oscillation frequency x 1.017 x 10-6 (Oscillation Frequency - Target Frequency) x 30 + 1
* 1) Oscillation frequency: Frequency of clock pulse output from the 32KOUT pin at normal temperature in the manner described in " P30 * Measurement of Oscillation Frequency". * 2) Target frequency: Desired frequency to be set. Generally, a 32.768-kHz quartz crystal unit has such temperature characteristics as to have the highest oscillation frequency at normal temperature. Consequently, the quartz crystal unit is recommended to have target frequency settings on the order of 32.768 to 32.76810 kHz (+3.05ppm relative to 32.768 kHz). Note that the target frequency differs depending on the environment or location where the equipment incorporating the RTC is expected to be operated. * 3) Oscillation adjustment value: Value that is to be finally written to the F0 to F6 bits in the Oscillation Adjustment Register and is represented in 7-bit coded decimal notation.
(2) When Oscillation Frequency Is Equal To Target Frequency (Causing Time Count neither Gain nor Loss)
Oscillation adjustment value = 0, +1, -64, or -63
(3) When Oscillation Frequency Is Lower Than Target Frequency (Causing Time Count Loss)
When DEV=0: Oscillation adjustment value = (Oscillation frequency - Target Frequency) Oscillation frequency x 3.051 x 10-6 (Oscillation Frequency - Target Frequency) x 10 When DEV=1: Oscillation adjustment value = (Oscillation frequency - Target Frequency) Oscillation frequency x 1.017 x 10-6 (Oscillation Frequency - Target Frequency) x 30 33
R2023K/T
Oscillation adjustment value calculations are exemplified below (A) For an oscillation frequency = 32768.85Hz and a target frequency = 32768.05Hz When setting DEV bit to 0: Oscillation adjustment value = (32768.85 - 32768.05 + 0.1) / (32768.85 x 3.051 x 10-6) (32768.85 - 32768.05) x 10 + 1 = 9.001 9 In this instance, write the settings (DEV,F6,F5,F4,F3,F2,F1,F0)=(0,0,0,0,1,0,0,1) in the oscillation adjustment register. Thus, an appropriate oscillation adjustment value in the presence of any time count gain represents a distance from 01h. When setting DEV bit to 1: Oscillation adjustment value = (32768.85 - 32768.05 + 0.0333) / (32768.85 x 1.017 x 10-6) (32768.85 - 32768.05) x 30 + 1 = 25.00 25 In this instance, write the settings (DEV,F6,F5,F4,F3,F2,F1,F0)=(1,0,0,1,1,0,0,1) in the oscillation adjustment register. (B) For an oscillation frequency = 32762.22Hz and a target frequency = 32768.05Hz When setting DEV bit to 0: Oscillation adjustment value = (32762.22 - 32768.05) / (32762.22 x 3.051 x 10-6) (32762.22 - 32768.05) x 10 = -58.325 -58 To represent an oscillation adjustment value of - 58 in 7-bit coded decimal notation, subtract 58 (3Ah) from 128 (80h) to obtain 46h. In this instance, write the settings of (DEV,F6,F5,F4,F3,F2,F1,F0) = (0,1,0,0,0,1,1,0) in the oscillation adjustment register. Thus, an appropriate oscillation adjustment value in the presence of any time count loss represents a distance from 80h. When setting DEV bit to 1: Oscillation adjustment value = (32762.22 - 32768.05) / (32762.22 x 1.017 x 10-6) (32762.22 - 32768.05) x 30 = -174.97 -175 Oscillation adjustment value can be set from -62 to 63. Then, in this case, Oscillation adjustment value is out of range.
(4) Difference between DEV=0 and DEV=1
Difference between DEV=0 and DEV=1 is following, DEV=0 -189.2ppm to 189.2ppm 3ppm DEV=1 --62ppm to 63ppm 1ppm
Maximum value range Minimum resolution
Notes: 1) Oscillation adjustment circuit does not affect the frequency of 32.768-kHz clock pulses output from the 32KOUT pin. 2) If following 3 conditions are completed, actual clock adjustment value could be different from target adjustment value that set by oscillator adjustment function. 1. Using oscillator adjustment function 34
R2023K/T
2. Access to R2023K/T at random, or synchronized with external clock that has no relation to R2023K/T, or synchronized with periodic interrupt in pulse mode. 3. Access to R2023K/T more than 2 times per each second on average. For more details, please contact to Ricoh.
*
How to evaluate the clock gain or loss
The oscillator adjustment circuit is configured to change time counts of 1 second on the basis of the settings of the oscillation adjustment register once in 20 seconds or 60 seconds. The oscillation adjustment circuit does not effect the frequency of 32768Hz-clock pulse output from the 32KOUT pin. Therefore, after writing the oscillation adjustment register, we cannot measure the clock error with probing 32KOUT clock pulses. The way to measure the clock error as follows: (1) Output a 1Hz clock pulse of Pulse Mode with interrupt pin Set (0,0,x,x,0,0,1,1) to Control Register 1 at address Eh. (2) After setting the oscillation adjustment register, 1Hz clock period changes every 20seconds ( or every 60 seconds) like next page figure.
1Hz clock pulse T0 T0 19 times T0 T1 1 time
Measure the interval of T0 and T1 with frequency counter. recommended for the measurement. (3) Calculate the typical period from T0 and T1 T = (19xT0+1xT1)/20 Calculate the time error from T.
A frequency counter with 7 or more digits is
35
R2023K/T
Power-on Reset, Oscillation Halt Sensing, and Supply Voltage Monitoring
*
PON, XST, and VDET
The power-on reset circuit is configured to reset control register1, 2, and clock adjustment register when VDD power up from 0v. The oscillation halt sensing circuit is configured to record a halt on oscillation by 32.768-kHz clock pulses. The supply voltage monitoring circuit is configured to record a drop in supply voltage below a threshold voltage of 1.6 or 1.3V. Each function has a monitor bit. I.e. the PON bit is for the power-on reset circuit, and XST bit is for the oscillation halt sensing circuit, and VDET is for the supply voltage monitoring circuit. PON and VDET bits are activated to "H". However, XST bit is activated to "L". The PON and VDET accept only the writing of 0, but XST accepts the writing of 0 and 1. The PON bit is set to 1, when VDD power-up from 0V, but VDET is set to 0, and XST is indefinite. The functions of these three monitor bits are shown in the table below. PON Monitoring for the power-on reset function D4 in Address Fh High 1 0 only
XST Monitoring for the oscillation halt sensing function D5 in Address Fh Low Indefinite
Function
Address Activated When VDD power up from 0v accept the writing
VDET a drop in supply voltage below a threshold voltage of 1.6 or 1.3V D6 in Address Fh High 0 0 only
Both 0 and 1
The relationship between the PON, XST , and VDET is shown in the table below. PON 0
XST
VDET 0
0
0
0
1
0
1
0
0
1
1
1
*
*
Conditions of supply voltage and oscillation Halt on oscillation, but no drop in VDD supply voltage below threshold voltage Halt on oscillation and drop in VDD supply voltage below threshold voltage, but no drop to 0V No drop in VDD supply voltage below threshold voltage and no halt in oscillation Drop in VDD supply voltage below threshold voltage and no halt on oscillation Drop in supply voltage to 0v
Condition of oscillator, and back-up status Halt on oscillation cause of condensation etc. Halt on oscillation cause of drop in back-up battery voltage Normal condition
No halt on oscillation, but drop in back-up battery voltage Power-up from 0v,
36
R2023K/T
Threshold voltage (2.1V or 1.35V) VDD 32768Hz Oscillation Power-on reset flag (PON) Oscillation halt sensing flag (XST) VDD supply voltage monitor flag (VDET) VDET0 XST1 PON0 VDET0 XST1 PON1 VDET0 XST1 PON0
Internal initialization period (1 to 2 sec.)
Internal initialization period (1 to 2 sec.)
When the PON bit is set to 1 in the control register 2, the DEV, F6 to F0, WALE, DALE, 12 /24, CLEN2 , TEST, CT2, CT1, CT0, VDSL, VDET, CLEN1 , CTFG, WAFG, and DAFG bits are reset to 0 in the oscillation adjustment register, the control register 1, and the control register 2. The PON bit is also set to 1 at power-on from 0 volts. < Considerations in Using Oscillation Halt Sensing Circuit > Be sure to prevent the oscillation halt sensing circuit from malfunctioning by preventing the following: 1) Instantaneous power-down on the VDD 2) Condensation on the quartz crystal unit 3) On-board noise to the quartz crystal unit 4) Applying to individual pins voltage exceeding their respective maximum ratings In particular, note that the XST bit may fail to be set to 0 in the presence of any applied supply voltage as illustrated below in such events as backup battery installation. Further, give special considerations to prevent excessive chattering in the oscillation halt sensing circuit.
VDD
37
R2023K/T
*
Voltage Monitoring Circuit
The supply monitoring circuit is configured to conduct a sampling operation during an interval of 7.8ms per second to check for a drop in supply voltage below a threshold voltage of 1.6 or 1.3v for the VDSL bit setting of 0 (the default setting) or 1, respectively, in the Control Register 2, thus minimizing supply current requirements as illustrated in the timing chart below. This circuit suspends a sampling operation once the VDET bit is set to 1 in the Control Register 2. The supply voltage monitor is useful for back-up battery checking.
VDD 1.6v or 1.3v PON
Internal initialization period (1 to 2sec.)
7.8ms 1s
Sampling timing for VDD supply voltage VDET (D6 in Address Fh) VDET0
PON0 VDET0
38
R2023K/T
Alarm and Periodic Interrupt
The R2023K/T incorporates the alarm interrupt circuit and the periodic interrupt circuit that are configured to generate alarm signals and periodic interrupt signals for output from the INTRA or INTRB pin as described below. (1) Alarm Interrupt Circuit The alarm interrupt circuit is configured to generate alarm signals for output from the INTRA or INTRB , which is driven low (enabled) upon the occurrence of a match between current time read by the time counters (the day-of-week, hour, and minute counters) and alarm time preset by the alarm registers (the Alarm_W registers intended for the day-of-week, hour, and minute digit settings and the Alarm_D registers intended for the hour and minute digit settings). The Alarm_W is output from the INTRB pin, the Alarm_D is output from INTRA pin. (2) Periodic Interrupt Circuit The periodic interrupt circuit is configured to generate either clock pulses in the pulse mode or interrupt signals in the level mode for output from the INTRA pin depending on the CT2, CT1, and CT0 bit settings in the control register 1. The above two types of interrupt signals are monitored by the flag bits (i.e. the WAFG, DAFG, and CTFG bits in the Control Register 2) and enabled or disabled by the enable bits (i.e. the WALE, DALE, CT2, CT1, and CT0 bits in the Control Register 1) as listed in the table below. Flag bits WAFG (D1 at Address Fh) DAFG (D0 at Address Fh) CTFG (D2 at Address Fh) Enable bits WALE (D7 at Address Eh) DALE (D6 at Address Eh) CT2=CT1=CT0=0 (These bit setting of "0" disable the Periodic nterrupt) (D2 to D0 at Address Eh) Output Pin INTRB
Alarm_W
Alarm_D
INTRA
Peridic interrupt
INTRA
* At power-on, when the WALE, DALE, CT2, CT1, and CT0 bits are set to 0 in the Control Register 1, the INTRA or INTRB pin is driven high (disabled). * When two types of interrupt signals are output simultaneously from the INTRA pin, the output from the INTRA pin becomes an OR waveform of their negative logic.
Example: Combined Output to INTRA Pin Under Control of ALARM_D and Periodic Interrupt Alarm_D Periodic Interrupt INTRA
In this event, which type of interrupt signal is output from the INTRA pin can be confirmed by reading the DAFG, and CTFG bit settings in the Control Register 2.
*
Alarm Interrupt
The alarm interrupt circuit is controlled by the enable bits (i.e. the WALE and DALE bits in the Control Register 1) and the flag bits (i.e. the WAFG and DAFG bits in the Control Register 2). The enable bits can be used to enable 39
R2023K/T
this circuit when set to 1 and to disable it when set to 0. When intended for reading, the flag bits can be used to monitor alarm interrupt signals. When intended for writing, the flag bits will cause no event when set to 1 and will drive high (disable) the alarm interrupt circuit when set to 0. The enable bits will not be affected even when the flag bits are set to 0. In this event, therefore, the alarm interrupt circuit will continue to function until it is driven low (enabled) upon the next occurrence of a match between current time and preset alarm time. The alarm function can be set by presetting desired alarm time in the alarm registers (the Alarm_W Registers for the day-of-week digit settings and both the Alarm_W Registers and the Alarm_D Registers for the hour and minute digit settings) with the WALE and DALE bits once set to 0 and then to 1 in the Control Register 1. Note that the WALE and DALE bits should be once set to 0 in order to disable the alarm interrupt circuit upon the coincidental occurrence of a match between current time and preset alarm time in the process of setting the alarm function.
Interval (1min.) during which a match between current time and preset alarm time occurs
INTRB (INTRA)
WALE1 current time = WALE0 preset alarm time (DALE) (DALE) WALE1 (DALE) current time = preset alarm time
INTRB (INTRA)
WALE1 current time = preset alarm time (DALE) WAFG0 (DAFG) current time = preset alarm time
After setting WALE(DALW) to 0, Alarm registers is set to current time, and WALE(DALE) is set to 1, INTRB ( INTRA ) will be not driven to "L" immediately, INTRB ( INTRA ) will be driven to "L" at next alarm setting time.
*
Periodic Interrupt
Setting of the periodic selection bits (CT2 to CT0) enables periodic interrupt to the CPU. There are two waveform modes: pulse mode and level mode. In the pulse mode, the output has a waveform duty cycle of around 50%. In the level mode, the output is cyclically driven low and, when the CTFG bit is set to 0, the output is return to High (OFF). CT2 CT1 CT0 Wave form mode 0 0 0 0 1 1 1 1 0 0 1 1 0 0 1 1 0 1 0 1 0 1 0 1 Pulse Mode *1) Pulse Mode *1) Level Mode *2) Level Mode *2) Level Mode *2) Level Mode *2) Description Interrupt Cycle and Falling Timing OFF(H) Fixed at "L" 2Hz(Duty50%) 1Hz(Duty50%) Once per 1 second (Synchronized with Second counter increment) Once per 1 minute (at 00 seconds of every Minute) Once per hour (at 00 minutes and 00 Seconds of every hour) Once per month (at 00 hours, 00 minutes, and 00 seconds of first day of every month) (Default)
40
R2023K/T
*1) Pulse Mode: 2-Hz and 1-Hz clock pulses are output in synchronization with the increment of the second counter as illustrated in the timing chart below.
CTFG Bit INTRA Pin Approx. 92s (Increment of second counter) Rewriting of the second counter
In the pulse mode, the increment of the second counter is delayed by approximately 92 s from the falling edge of clock pulses. Consequently, time readings immediately after the falling edge of clock pulses may appear to lag behind the time counts of the real-time clocks by approximately 1 second. Rewriting the second counter will reset the other time counters of less than 1 second, driving the INTRA pin low. *2) Level Mode: Periodic interrupt signals are output with selectable interrupt cycle settings of 1 second, 1 minute, 1 hour, and 1 month. The increment of the second counter is synchronized with the falling edge of periodic interrupt signals. For example, periodic interrupt signals with an interrupt cycle setting of 1 second are output in synchronization with the increment of the second counter as illustrated in the timing chart below.
CTFG Bit INTRA Pin Setting CTFG bit to 0 (Increment of second counter) (Increment of second counter) Setting CTFG bit to 0 (Increment of second counter)
*1), *2) When the oscillation adjustment circuit is used, the interrupt cycle will fluctuate once per 20sec. as follows: Pulse Mode: The "L" period of output pulses will increment or decrement by a maximum of 3.784ms. For example, 1-Hz clock pulses will have a duty cycle of 50 0.3784%. Level Mode: A periodic interrupt cycle of 1 second will increment or decrement by a maximum of 3.784 ms.
41
R2023K/T
*
32-kHz CLOCK OUTPUT
For the R2023K/T, 32.768-kHz clock pulses are output from the 32KOUT pin when either the CLEN1 bit in the Control Register 2 or the CLEN2 bit in the Control Register 1 is set to 0 when the CLKC pin is set to high. If the condition is not satisfied, the output is set to low.
CLEN1 (D3 at Address Fh) 1 * 0(Default) * CLEN2 (D4 at Address Eh) 1 * * 0(Default)
CLKC pin input * 0 1 1
32KOUT PIN (CMOS push-pull output) "L" Clock pulses
The 32KOUT pin output is synchronized with the CLEN1 and CLEN2 bit and CLKC pin settings as illustrated in the timing chart below.
CLKC pin or CLEN1 or CLEN2 bit setting 32KOUT PIN
Max.62.0s
42
R2023K/T
Typical Applications
*
Typical Power Circuit Configurations
Sample circuit configuration 1 R1163xxx1B is a series regulator with the reverse current protection circuit. The CE pin should be pull-up to system power supply voltage, and ECO pin should be connect to system power supply or VSS. Please select VOUT voltage equal to the CPU power supply voltage that interfaces to R2023K/T and SRAM.
System Power Supply
VDD
VOUT
VDD
*1) Install bypass capacitors for high-frequency and low-frequency applications in parallel in close vicinity to the R2023K/T.
R1163xxx1B SRAM etc. Primary Battery VSS CE ECO
VSS
Sample circuit configuration 2
OSCIN OSCOUT VDD 32768Hz System power supply
VSS
Primary Battery
OSCIN OSCOUT VDD 32768Hz
System power supply
VSS
Secondary Battery
43
R2023K/T
*
Connection of INTRA or INTRB Pin
The INTRA or INTRB pin follows the N-channel open drain output logic and contains no protective diode on the power supply side. As such, it can be connected to a pull-up resistor of up to 5.5v regardless of supply voltage.
System power supply
INTRA or INTRB OSCIN OSCOUT VDD VSS 32768Hz
A *1) B Backup power supply
*1) Depending on whether the INTRA or INTRB pin is used during battery backup, it should be connected to a pull-up resistor at the following different positions: (1) Position A in the left diagram when it is not to be used during battery backup. (2) Position B in the left diagram when it is to be used during battery backup.
*
Connection of 32KOUT Pin
As the 32KOUT pin is CMOS output, the supply voltage of the R2023K/T and any devices to be connected should be the same. When the device is powered down, the 32KOUT output pin should be disabled. When the CLKC pin is connected to the system power supply through the pull-up resistor, the pull-up resistor should be 0 to 10k, and the 32KOUT pin should be connect to the host device through the resistor (approx. 10k)
CLKC 32KOUT
R3111 XXXXC
CPU Power Supply CLKC 32KOUT
0 to 10K
CPU Power Supply CPU
Approx.10K Back-up Power Supply Back-up Power supply
VDD VSS
VDD VSS
44
R2023K/T
Typical Characteristics
Test circuit

VDD OSCIN CGOUT 32768Hz OSCOUT CDOUT 32KOUT VSS Frequency Counter
X'tal : 32.768kHz (R1=50k typ) (CL=6pF to 9pF) Topt : 25C Output pins : Open
Timekeeping Current vs. Supply Voltage (with no 32kHz clock output) (Output=Open, Topt=25C)
Timekeeping Current IDD(uA)
Timekeeping Current vs. Supply Voltage (with 32kHz clock output) (Output=Open, Topt=25C)
Timekeeping Current IDD(uA)
1 0.8 0.6 0.4 0.2 0 0 1 2 3 4 5 6 Supply Vlotage VDD(v)
2.5 2 1.5 1 0.5 0 0 1 2 3 4 5 6 Supply Voltage VDD(v)
(CGout, CDout)=(5pF, 5pF)
(CGout, CDout)=(5pF, 5pF) (CGout, CDout)=(0pF, 0pF)
(CGout, CDout)=(0pF, 0pF)
CPU Access Current vs. SCL Clock Frequency (CLKC=VSS, Output pins=Open, Topt=25C, CGout=CDout=0pF)
CPU Access Current IDD(uA)
Timekeeping Current vs. Operating Temperature (VDD=3v, Output pins=Open, CGout=CDout=0pF)
Timekeeping Current IDD(uA)
40 30 20
VDD=5v
VDD=3v
10 0 0 100 200 300 400 500 SCL Clock Frequency (kHz)
2 1.8 1.6 1.4 1.2 1 0.8 0.6 0.4 0.2 0
with 32kHz clock output
with no 32kHz clock output
-50
-25
0
25
50
75
100
Operating Temperature Topt(Celcius)
45
R2023K/T
Oscillation Frequency Deviation vs. External CF, CD (VDD=3v, Topt=25C, CGout=CDout=0pF as standard)
Oscillation Frequency Deviation (ppm)
Oscillation Frequency Deviation vs. Supply Voltage (Topt=25C,VDD=3v as standard)
Oscillation Frequency Deviation (ppm)
0 -10 -20 -30 -40 -50 -60 -70 -80 -90 -100 0 5
CDout=0pF
CDout=5pF
5 4 3 2 1 0 -1 -2 -3 -4 -5 0 1 2 3 4 5 6 Supply Voltage VDD (v)
10
15
20
External CG (pF)
Oscillation Frequency Deviation vs. Operating Temperature (VDD=3V, Topt=25C as standard)
Oscillation Frequency Deviation (ppm)
VOL vs. IOL (SCL pin) (Topt=25C)
20 0 -20 -40 -60 -80 -100 -120 -60 -40 -20 0 20 40 60 80 10 0 Operating TemperatureTopt(Celsius)
30 25
IOL (mA)
VDD=5v
20 15 10 5 0 0 0.1 0.2 0.3 0.4 0.5 VOL (v)
VDD=3v
VDD=1.7v
VOL vs. IOL ( INTRA , INTRB pin) (Topt=25C)
30 25
IOL(mA)
VDD=5v VDD=3v VDD=1.5v
20 15 10 5 0 0 0.1 0.2 0.3 0.4 0.5 VOL(v)
46
R2023K/T
Typical Software-based Operations
*
Initialization at Power-on
Start *1) Power-on *2)
PON=1?
No *3)
VDET=0?
Yes
*4) Yes
Set Oscillation Adjustment Register and Control Register 1 and 2, etc.
No
Warning Back-up Battery Run-down
*1) After power-on from 0 volt, the start of oscillation and the process of internal initialization require a time span on 1to 2seconds, so that access should be done after the lapse of this time span or more. *2) The PON bit setting of 0 in the Control Register 1 indicates power-on from backup battery and not from 0v. For further details, see "P.36 * PON, XST , VDET". *3) This step is not required when the supply voltage monitoring circuit is not used. *4) This step involves ordinary initialization including the Oscillation Adjustment Register and interrupt cycle settings, etc.
*
Writing of Time and Calendar Data
*1) When writing to clock and calendar counters, do not insert Stop Condition until all times from second to year have been written to prevent error in writing time. (Detailed in "P.28 Data Transmission under Special Condition". *2) Any writing to the second counter will reset divider units lower than the second digits. *3) Take care so that process from Start Condition to Stop Condition will be complete within 0.5sec. (Detailed in "P.28 Data Transmission under Special Condition". The R2023K/T may also be initialized not at power-on but in the process of writing time and calendar data.
*1)
Start Condition
Write to Time Counter and Calendar Counter
*2)
Stop Condition
*3)
47
R2023K/T
*
Reading Time and Calendar Data
(1) Ordinary Process of Reading Time and Calendar Data
*1) When reading to clock and calendar counters, do not insert Stop Condition until all times from second to year have been written to prevent error in writing time. (Detailed in "P.28 Data Transmission under Special Condition". *2) Take care so that process from Start Condition to Stop Condition will be complete within 0.5sec. (Detailed in "P.28 Data Transmission under Special Condition".
*1)
Start Condition
Read from Time Counter and Calendar Counter
Stop Condition
*2)
(2) Basic Process of Reading Time and Calendar Data with Periodic Interrupt Function
Set Periodic Interrupt Cycle Selection Bits
*1)
Generate Interrupt in CPU
CTFG=1?
No *2)
Yes
Read from Time Counter and Calendar Counter
Other Interrupt Processes
*1) This step is intended to select the level mode as a waveform mode for the periodic interrupt function. *2) This step must be completed within 0.5 second. *3) This step is intended to set the CTFG bit to 0 in the Control Register 2 to cancel an interrupt to the CPU.
*3)
Control Register 2 (X1X1X011)
48
R2023K/T
(3) Applied Process of Reading Time and Calendar Data with Periodic Interrupt Function
Time data need not be read from all the time counters when used for such ordinary purposes as time count indication. This applied process can be used to read time and calendar data with substantial reductions in the load involved in such reading. For Time Indication in "Day-of-Month, Day-of-week, Hour, Minute, and Second" Format:
Control Register 1 (XXXX0100) Control Register 2 (X1X1X011)
*1)
Generate interrupt to CPU Other interrupts Processes
CTFG=1?
No *2)
Yes
Sec.=00?
*1) This step is intended to select the level mode as a waveform mode for the periodic interrupt function. *2) This step must be completed within 0.5 sec. *3) This step is intended to read time data from all the time counters only in the first session of reading time data after writing time data. *4) This step is intended to set the CTFG bit to 0 in the Control Register 2 to cancel an interrupt to the CPU.
No *3)
Use previous Min.,Hr., Day, and Day-of-week data
Yes
Read Min.,Hr.,Day, and Day-of-week
Control Register 2 (X1X1X011)
*4)
49
R2023K/T
*
Interrupt Process
(1) Periodic Interrupt
Set Periodic Interrupt Cycle Selection Bits
*1)
Generate Interrupt to CPU
*1) This step is intended to select the level mode as a waveform mode for the periodic interrupt function. *2) This step is intended to set the CTFG bit to 0 in the Control Register 2 to cancel an interrupt to the CPU.
No
Other Interrupt Processes
CTFG=1? Yes
Conduct Periodic Interrupt
*2)
Control Register 2 (X1X1X011)
(2) Alarm Interrupt
WALE or DALE0
*1)
Set Alarm Min., Hr., and Day-of-week Registers
WALE or DALE1
*2)
Generate Interrupt to CPU
*1) This step is intended to once disable the alarm interrupt circuit by setting the WALE or DALE bits to 0 in anticipation of the coincidental occurrence of a match between current time and preset alarm time in the process of setting the alarm interrupt function. *2) This step is intended to enable the alarm interrupt function after completion of all alarm interrupt settings. *3) This step is intended to once cancel the alarm interrupt function by writing the settings of "X,1,X, 1,X,1,0,1" and "X,1,X,1,X,1,1,0" to the Alarm_W Registers and the Alarm_D Registers, respectively.
WAFG or DAFG=1?
No Other Interrupt
Processes
Yes
Conduct Alarm Interrupt
*3)
Control Register 2 (X1X1X101)
50


▲Up To Search▲   

 
Price & Availability of R2023T-E2

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X